Japanese     
1. Summary:
2. Applied reference materials:
3. Publications used this instrument: 2024-2, 2023-11, 2023-1, 2022-2, 2019-2
1. Summary: Separation and detection system for relatively volatile organic
compounds. This instrument provides quite high mass selectivity.
2. Applied reference materials: CRM 7304-a, CRM 7404-a, CRM 7407-a, CRM 7906-a, CRM
7902-a, CRM 7903-a, CRM 7904-a, CRM 7905-a, CRM 7906-a
3. Publications used this instrument: 2010-3, 2008-9, 2008-4, 2008-3, 2007-5,
2007-1, 2006-5, 2006-2, 2006-1, 2005-2, 2004-2, 2004-1, 2003-4, 2003-2
1. Summary: Separation and detection system for relatively volatile organic
compounds. This instrument provides higher mass selectivity than GC-QMS.
1. Summary: Separation and detection system for relatively volatile organic
compounds. This instrument provides high mass selectivity.
2. Applied reference materials: CRM 7307-a, CRM 7308-a, CRM 7504-a, CRM
7507-a, CRM 7508-a, CRM 7509-a, CRM 7510-a, CRM 8301-a
3. Publications used this instrument: 2023-10, 2023-9, 2020-5, 2017-2, 2017-1, 2016-3, 2016-2, 2016-1,
2015-6, 2015-4, 2015-2, 2015-1, 2014-8, 2014-7,2014-2, 2014-1, 2013-4, 2012-4,2012-3, 2012-1, 2011-4, 2011-3, 2011-2, 2011-1, 2010-4,
2010-2, 2010-1, 2009-4, 2009-3, 2009-2, 2008-10, 2008-8, 2008-6, 2008-5, 2008-2, 2008-1, 2007-4, 2007-3, 2006-4
1. Summary: Separation and detection system for relatively volatile organic
compounds. This instrument provides better separation property.
3. Publications used this instrument: 2020-3, 2013-3
1. Summary: Separation and detection system for relatively volatile organic
compounds. This instrument provides universal detection.
2. Applied reference materials: CRM 4213-a, CRM 8301-a
3. Publications used this instrument: 2022-1, 2015-3, 2015-1, 2011-2, 2010-1, 2008-5
1. Summary: Separation and detection system for organic compounds at liquid
state. This provides high mass selectivity, especially for MS/MS.
2. Applied reference materials: CRM 4056-a, CRM 4220-a, CRM 7307-a, CRM
7407-a, CRM 8155-a
3. Publications used this instrument: 2023-4, 2020-5, 2020-2, 2020-1, 2019-3, 2018-4, 2018-2, 2018-1, 2014-8, 2014-5,
2014-3, 2013-6, 2013-5, 2009-5, 2009-3, 2009-1, 2006-3
1. Summary: Separation and detection system of organic compounds at liquid
state. This instrument provides selective and highly-sensitive detection of fluorescence compounds.
1. Summary: Separation and detection system of organic compounds at liquid state. This instrument provides better separation property.
1. Summary: Separation and detection system of organic compounds at liquid
state. This instrument provides universal detection.
1. Summary: Extraction and chromatography system of organic compoundsusing supercritical CO2 instead of organic solvents.
2. Applied reference materials: CRM 7304-a
3. Publications used this instrument: 2023-4, 2020-1, 2007-1, 2006-5
1. Summary: Instrument for determination of water contents in liquid/solid
materials. The glove box enables to quantify water contents at trace level.
2. Applied reference materials: CRM 4001-b, CRM 4056-a, CRM 4222-a, CRM
4228-a, CRM 4229-a,CRM 8301-a, CRM 8302-a
3. Publications used this instrument: 2018-3, 2016-4, 2015-5, 2015-1, 2014-6,
2014-5, 2014-3, 2013-6, 2013-5, 2012-2, 2011-2, 2010-1
1. Summary: Instruments for extraction of target organic compounds from solid matrices. Heating of extraction media enhances extraction efficiency.
2. Applied reference materials: CRM 7307-a, CRM 7308-a, CRM 7404-a, CRM
7504-a
3. Publications used these instruments: 2017-1, 2015-6, 2014-2, 2012-4,
2011-4, 2011-1, 2010-4, 2010-3, 2010-2, 2009-4, 2009-3, 2008-10, 2008-8,
2008-6, 2008-4, 2008-2, 2008-1, 2007-4, 2007-3, 2007-1, 2006-4, 2006-1, 2005-2, 2004-2, 2003-2
1. Summary: Instrument for filling solutions into ampoules and sealing.
The vacant space can be replaced with Ar gas not to oxidize the contents.
2. Applied reference materials: CRM 4222-a, CRM 8301-a, CRM 8302-a
3. Publications used this instrument: 2016-4, 2014-8, 2014-6, 2013-5, 2012-2
1. Summary: This clean room is class 10000 and enables to prepare calibration
solutions without contamination under controlled temperature and humidity.
Our group also use other instruments such as fluorescence microscopes, Raman microscopes, scanning electron microscopes of common utilities or other groups.