4.3. Radiometric Correction Data |
|
DN values can be converted into Radiance as follows.
L = A V /G + D (VNIR and SWIR bands)
L = AV + CV2 + D (TIR bands)
Where
L: radiance (W/m2/sr/μm)
A : linear coefficient
C : nonlinear coefficient
D : offset
V : DN value
G : gain
The radiometric correction table can be extracted from the HDF file.
Figures 4-4 shows the structure of radiometric coefficients.
Figure 4-5 shows the relationship between detector number and image pixel position.
Note that this relationship is reversed for the VNIR and SWIR bands: the detector
#1 corresponds to the left end column pixels for VNIR bands, while it corresponds to the right end column pixels for SWIR bands.
Figure 4-4 Structure of radiometric coefficients
Figure 4-5 Relationship between detector number and image pixel position
|
|
|
|
|